Find the 20W you're leaking

Ten minutes. Often worth a whole battery.

Waking to a lower state of charge than the math predicts is one of the most common off-grid complaints. Usually there's a phantom load.

A phantom load is something drawing power while you believe everything is off. Individually small. Around the clock, real capacity.

The usual suspects: an inverter left on. Stereo memory circuits, backup cameras, alarms. A propane/CO detector — necessary, keep it, but count it. Chargers with nothing plugged in. A fridge control board in standby. Router and cell booster left on overnight.

How to find it in ten minutes: 1. Turn off everything you believe you can 2. Watch the current reading on your battery monitor — this is where a shunt earns its cost 3. Whatever remains is your phantom load. Multiply by 24 for daily cost. 4. Pull fuses one at a time and watch the number drop

No shunt? A clamp meter on the main negative does the same job.